The -70℃ explosion-proof water-cooled chiller adopts a cascade two-stage compression water-cooled refrigeration system with full explosion-proof construction. It can stably supply heat transfer medium at -70℃ with temperature control accuracy up to ±0.1℃. All electrical components comply with national explosion-proof standard Ex d ⅡB T4 (Ex d ⅡC T4 optional). Featuring high-efficiency water cooling and 304/316L sanitary stainless steel pipelines, the unit meets GMP standards for pharmaceutical clean workshops. It is specially designed for pharmaceutical workshops, biological labs and medical lyophilization areas with flammable volatile organic solvents and high-oxygen explosion hazardous zones.

  • Số mục :

    BS-45FD-EX
  • Đơn hàng (MOQ) :

    1
  • Sự chi trả :

    EXW/FOB/CIF/FCA/DPU/DDU
  • Nguồn gốc sản phẩm :

    CHINA
  • Màu sắc :

    Customizable
  • Cảng vận chuyển :

    SHANGHAI/NANJING
  • Thời gian dẫn :

    28
  • Cân nặng :

    650kg
Water cooled packaged chiller

BS Series Water Cooled Packaged Chiller

  • Temperature range: -70℃ ~ +30℃ adjustableTemperature control accuracy: ±0.1℃
  • Cooling method: Water-cooled (matched with industrial cooling tower)
  • Explosion-proof grade: Ex d ⅡB T4 Gb (Ex d ⅡC T4 optional)
  • Circulation pipeline: 304/316L sanitary stainless steel
  • Heat transfer medium: Medical low-toxic food-grade ethylene glycol solution

  • Continuous operation: 24-hour non-stop all-year running

Water cooled  packaged chiller Working Principle

Medical manufacturing widely adopts flammable volatile solvents such as ethanol, acetone, dichloromethane and DMSO. Lyophilization, API synthesis and sample pretreatment areas are classified as Zone 1 & Zone 2 explosive gas hazardous locations:
 
Complete flameproof electrical system: Explosion-proof compressors, explosion-proof motors, flameproof control cabinets, explosion-proof sensors and sealed cable glands eliminate electric sparks that may ignite solvent vapor.Anti-static safety
 
structure: All pipelines, frames and circulating pumps are equipotentially bonded and grounded to prevent static accumulation. Spark-free impellers avoid sparks from metal collision. The maximum surface temperature of the unit is lower than the ignition point of common medical organic solvents.
 
Multi-channel safety interlock protection: Automatic shutdown and audible-visual alarm triggered by over-temperature, high/low refrigerant pressure, insufficient flow, phase loss, overload and medium leakage, fully complying with medical safety supervision standards.

 

Safety Protection Function

  • Stable cooling capacity: Dissipate heat via external cooling towers, free from ambient high temperature impact. Constant refrigeration output during 24-hour non-stop production, ideal for three-shift pharmaceutical manufacturing.
  • Cleanroom compatible: No hot air exhaust to avoid disrupting cleanroom pressure difference, temperature and humidity balance. Low noise operation without interference to precision medical testing equipment.
  • Easy cleaning & sterilization: Mirror-polished stainless steel pipelines with no sanitary dead corners, supporting CIP online cleaning and resisting corrosion, suitable for vaccine and biologic clean production zones.

 

  • Energy-saving performance: Compared with air-cooled explosion-proof low-temperature chillers of the same specification, cooling efficiency increases by over 25% under high-temperature working conditions, cutting long-term operation costs.

FAQ

Q1:What are the requirements for the operating environment of the water chiller?

A1: Generally, the ambient temperature is required to be between 5℃ and 40℃, and the relative humidity should not exceed 85%. At the same time, the water chiller should be placed in a well-ventilated area free from direct sunlight, and away from heat sources and dust. This ensures the normal operation of the water chiller and optimal heat dissipation performance.

 

Q2: What are the causes of poor cooling efficiency in the water chiller?

A2: Possible causes include the following:

 
  • Insufficient cooling water flow: Check if the cooling water pump is working properly and if there is any blockage in the pipes.
  • Excessively high cooling water temperature: Inspect whether the cooling tower is operating normally and ensure unobstructed circulation of the cooling water.
  • Contamination accumulation in the condenser: Regularly clean the condenser to maintain its heat dissipation performance.
  • Refrigerant leakage: Examine the refrigeration system to locate and repair the leakage points.

 

Q3: What causes excessive noise from the water chiller?

A3: Common causes are as follows:

  • Vibration of the cooling water pump: Check if the pump is installed securely and if its bearings are worn.
  • Motor failure: Inspect the insulation performance of the motor and check for bearing wear.
  • Malfunction of the cooling tower fan: Verify if the fan blades are balanced and check for bearing wear.
  • Refrigerant leakage: This can also lead to excessive noise. Inspect the refrigeration system to find and fix the leakage points.

 

Model And Technical Parameter

Model Unit 03WS 05WS 08WS 10WD 12WS 15WD
Temp. control range Inlet water temperature -5-25℃
Temp. accuracy PID±1℃
Power AC3Φ380V 50HZ 3P+E(5M)
Heat transfer medium Water
Cooling methad Indirect cooling
Refrigeration capacity KW 9.2 15.3 24.6 32.5 37.6 48.5
Pump power HP 0.5 1 2 3 5 7.5
Max.pump flow L/min 95 165 236 315 385 415
Max.pump pressure Bar 2 2.2 2.4 2.6 2.8 3
Pump  Power KW 0.55 0.55 1.1 1.5 1.5 1.5
Evaporator(Water Flow) m³/h 2 3 5 6 7 9
Tank Volume L 55 75 150 150 150 200
Dimension(mm) L 900 900 1300 1300 1450 1450
W 650 650 800 800 900 900
H 1300 1300 1500 1500 1550 1550
Weight kg 150 220 310 360 450 650

 

Note: The specification is subject to change due to product improvement without prior notice.

 

Process Flow Diagram

 

 

 

Application Case

Our oil temperature control unit is widely used across various industrial applications, including casting moulds, rubber vulcanization, wheel temperature control, hot press technology, carbon fiber production, and chemical reactions. It ensures precise temperature management, improving production efficiency and product quality in these processes.

 

Our Partner 

 

Customized Solutions for Your Business, Contact Us Quickly!

 

Để lại tin nhắn
Nếu bạn quan tâm đến sản phẩm của chúng tôi và muốn biết thêm chi tiết, vui lòng để lại tin nhắn tại đây, chúng tôi sẽ trả lời bạn sớm nhất có thể.

Sản phẩm liên quan

-15℃ water cooled packaged chiller
Hệ thống làm lạnh bằng nước khép kín, điều khiển nhiệt độ chính xác, dùng để làm mát trong sản xuất hydro tại ngành công nghiệp thủy tinh.

Thiết bị làm lạnh công nghiệp có điều khiển nhiệt độ chủ yếu được sử dụng để cung cấp môi chất làm lạnh ở nhiệt độ thấp ổn định cho các quy trình sản xuất công nghiệp khác nhau. Nó đặc biệt phù hợp với các quy trình sản xuất hydro, vốn nhạy cảm với sự biến động nhiệt độ và có yêu cầu nghiêm ngặt về chất lượng nước.

ĐỌC THÊM
7℃ water cooled packaged chiller
Máy làm lạnh nước đóng gói - Dòng BS (7℃) -08WS

Máy làm lạnh đóng gói giải nhiệt bằng nước là thiết bị công nghiệp đạt hiệu quả làm lạnh thông qua chu trình làm mát bằng nước và được sử dụng rộng rãi trong các trường hợp yêu cầu kiểm soát nhiệt độ chính xác.

ĐỌC THÊM
7℃ water cooled packaged chiller
Máy làm lạnh nước đóng gói giải nhiệt bằng nước máy nén đơn - Dòng BS (-5℃) -03WSM

Máy làm lạnh dạng hộp giải nhiệt bằng nước -5℃ là thiết bị dạng hộp tích hợp chuyên cung cấp nước làm mát nhiệt độ thấp dưới 5℃ và chủ yếu được sử dụng trong các tình huống sản xuất công nghiệp yêu cầu kiểm soát nhiệt độ thấp.

ĐỌC THÊM
7℃ air cooled packaged chiller
Máy làm lạnh nước đóng gói giải nhiệt bằng không khí - Dòng BS 1hp 7℃ - BS-01AS

Máy làm lạnh nước đóng gói giải nhiệt bằng không khí là thiết bị làm lạnh nước tích hợp sử dụng không khí làm môi trường làm mát. Chức năng cốt lõi của nó là cung cấp nước lạnh nhiệt độ thấp cho sản xuất công nghiệp hoặc thương mại.

ĐỌC THÊM
-5℃ air cooled packaged chiller
Máy làm lạnh nước đóng gói giải nhiệt bằng không khí máy nén đôi - Dòng BS (-5℃) - 10AD

Máy làm lạnh nước đóng gói giải nhiệt bằng không khí là thiết bị làm lạnh nước tích hợp sử dụng không khí làm môi trường làm mát. Chức năng cốt lõi của nó là cung cấp nước lạnh nhiệt độ thấp cho sản xuất công nghiệp hoặc thương mại.

ĐỌC THÊM
Air cooled packaged chiller
Nhà sản xuất thiết bị làm lạnh bằng nước dạng hộp làm mát bằng không khí bằng thép không gỉ công nghiệp.

Chúng tôi là nhà sản xuất chuyên nghiệp tập trung vào nghiên cứu, phát triển, sản xuất và phân phối toàn cầu các thiết bị làm lạnh hộp bằng thép không gỉ làm mát bằng không khí và các thiết bị làm mát bằng nước cho công nghiệp. Với hơn 20 năm kinh nghiệm trong lĩnh vực làm lạnh công nghiệp, chúng tôi cung cấp các giải pháp làm mát mạnh mẽ, hiệu quả cao, được thiết kế riêng cho sản xuất chính xác, chế biến hóa chất, mạ điện, dược phẩm, thiết bị laser và nhiều ứng dụng công nghiệp nặng khác.

ĐỌC THÊM
7℃ water cooled packaged chiller
Máy làm lạnh nước dạng hộp 7℃ | Nhà sản xuất máy làm lạnh nước công nghiệp

Chúng tôi chuyên nghiên cứu, phát triển, sản xuất và kinh doanh máy làm lạnh nước dạng hộp tiêu chuẩn 7°C. Với thiết kế dạng hộp tích hợp, thiết bị bao gồm bình chứa nước cách nhiệt bằng thép không gỉ, bơm nước lạnh áp suất cao và hệ thống điều khiển điện tử thông minh. Sản phẩm được giao dưới dạng thiết bị hoàn chỉnh, dễ dàng lắp đặt và bảo trì, cho phép sử dụng ngay lập tức.

ĐỌC THÊM
-70℃ water cooled packaged chiller
-70℃ Explosion-Proof Water-Cooled Chiller for Medical Industry-BS-45FD

The -70℃ explosion-proof water-cooled chiller adopts a cascade two-stage compression water-cooled refrigeration system with full explosion-proof construction. It can stably supply heat transfer medium at -70℃ with temperature control accuracy up to ±0.1℃. All electrical components comply with national explosion-proof standard Ex d ⅡB T4 (Ex d ⅡC T4 optional). Featuring high-efficiency water cooling and 304/316L sanitary stainless steel pipelines, the unit meets GMP standards for pharmaceutical clean workshops. It is specially designed for pharmaceutical workshops, biological labs and medical lyophilization areas with flammable volatile organic solvents and high-oxygen explosion hazardous zones.

ĐỌC THÊM

Để lại tin nhắn

Để lại tin nhắn
Nếu bạn quan tâm đến sản phẩm của chúng tôi và muốn biết thêm chi tiết, vui lòng để lại tin nhắn tại đây, chúng tôi sẽ trả lời bạn sớm nhất có thể.
nộp

Trang chủ

Các sản phẩm

WhatsApp

liên hệ